The Port Status screen can be used to ensure data is entering and exiting the sensor. This can be useful for debugging
issues such as improper wiring, mismatched baud rates, or other serial I/O issues.
Industrial Ethernet
Main Menu > System
> Communications > Industrial Ethernet
The iVuPlus device can be controlled or monitored over Industrial Ethernet using Ethernet/IP, Modbus/TCP or PCCC
protocols. This document will help you to set up the iVu Plus in the desired configuration and provide you with information
you will need to connect to the master device (PLC, HMI, etc.).
Connection
Main Menu > System > Communications > Industrial Ethernet > Connection
The Connection screen is used to enable either Modbus or EIP/PCCC protocols on Industrial Ethernet channel. Select
'Disable' to completely disable Industrial Ethernet channel.
Map
Main Menu > System > Communications > Industrial Ethernet > Map
The Map setting (Default/Custom) affects only on EIP assembly 0×65 or MODBUS/PCCC registers 30001 to 30240 at offset
55-166.
Default Map
Main Menu > System > Communications > Industrial EtherNet > Map > Default
The default map automatically maps sensor data for each inspection and is recommended when the execution order of
sensor types is the same across inspections. When an inspection has multiple sensors, the first five sensor results are
shown starting at offset 55. Each sensor result occupies 20 words.
Table 5: EIP Assembly Instance 101 (0x65): DEFAULT MAP
WORD # WORD NAME Data Type
0 Input Bits ACK Register (see Input and Output Flags Bits
on page 115) 16-bit integer
1 Output Bits Register (see Input and Output Flags Bits on page 115) 16-bit integer
2-3 Error Code 32-bit integer
4-5 Inspection Number 32-bit integer
6-7 Iteration Count 32-bit integer
8-9 Pass Count 32-bit integer
10-11 Fail Count 32-bit integer
12-13 Missed Triggers 32-bit integer
14-15 Current Inspection Time Float
16 Sensor Pass/Fail Coil 16-bit integer
17-29 reserved 16-bit integer
30-52 Inspection Name 2-Word Length + 20-Unicode chars
iVu Plus TG Gen2 Image Sensor