Sensor Specific Data Sensor Location
Sort Pattern Count 16-bit integer
Sort Pattern 1 Count 16-bit integer
Sort Pattern 2 Count 16-bit integer
Sort Pattern 3 Count 16-bit integer
Sort Pattern 4 Count 16-bit integer
Sort Pattern 5 Count 16-bit integer
Sort Pattern 6 Count 16-bit integer
Sort Pattern 7 Count 16-bit integer
Sort Pattern 8 Count 16-bit integer
Sort Pattern 9 Count 16-bit integer
Sort Pattern 10 Count 16-bit integer
Sort Min Percent Match 16-bit integer
Sort Max Percent Match 16-bit integer
Custom Map
Main Menu > System > Communications
> Industrial EtherNet > Map > Custom
The custom map allows for customization of sensor data on the map. The user selects data items of interest for each
sensor type. This is recommended when the execution order of sensor types varies across inspections or when using more
than five sensors.
A system level custom map is supported for additional flexibility. When custom map is selected, a customizable space is
used in the offset range (55 to 166) on EIP Assembly 101 (0x65) registers.
Table 10: EIP Assembly Instance 101 (0x65): CUSTOM MAP
WORD # WORD NAME Data Type
0 Input Bits ACK Register (see Input and Output Flags Bits
on page 115) 16-bit integer
1 Output Bits Register (see Input and Output Flags Bits on page 115) 16-bit integer
2-3 Error Code 32-bit integer
4-5 Inspection Number 32-bit integer
6-7 Iteration Count 32-bit integer
8-9 Pass Count 32-bit integer
10-11 Fail Count 32-bit integer
12-13 Missed Triggers 32-bit integer
14-15 Current Inspection Time Float
16 Sensor Pass/Fail Coil 16-bit integer
17-29 reserved 16-bit integer
30-52 Inspection Name 2-Word Length + 20-unicode chars
53-54 Frame Number 32-bit integer
55-166 Customizable Space (112 reg) 16-bit integer
167-170 reserved 16-bit integer
171 Command Status 16-bit integer
172 Command Response Int16 16-bit integer
173-174 Command Response Int32 32-bit integer
175-176 Command Response Float Float
177-178 Command Response Length 32-bit integer
179-228 Command Response Data 100 Byte Array
229-239 reserved 16-bit integer
iVu Plus TG Gen2 Image Sensor
www.bannerengineering.com - Tel: 763.544.3164 43