EasyManuals Logo

Basler GigE SERIES User Manual

Basler GigE SERIES
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #371 background imageLoading...
Page #371 background image
AW00089317000 Revision History
Basler ace GigE 361
AW00089316000 8 Aug 2012 Section 10
Updated the minimum gain setting for the acA2000 and acA2040
models in Table 29 on page 200 and Table 30 on page 201.
Inserted information in Section 10.6 on page 219 that the stacked zone
imaging feature on the acA2000-50 and acA2040-25 increases the
camera’s frame rate.
In the sequencer feature Section 10.8:
Entered sequencer parameters that are stored in the factory set.
Added that overlapped operation is not possible for the acA2500-14
with the sequencer feature enabled.
Added the vertical decimation feature in Section 10.10.1 on page 264.
Added Section 10.13.3.1 on page 279 describing the assignment of an
auto function to an auto function AOI.
Added the gray value adjustment damping feature in Section 10.13.6 on
page 289.
AW000893
17000 15 Aug 2014 Updated the mail addresses and the Asian contact address (page 3).
Removed the "in preparation" from the term "UL (in preparation) in the
tables in Section 1.2 on page 2.
Updated the sensor size of the acA1600-20gm (height: 1626 instead of
1628).
Added warnings on avoiding dust on the sensor in Section 1.8 on page 40.
Changed the name of the acA640-100gm/gc camera model to acA640-
120gm/gc.
Renaming throughout the manual: Changed
pylon driver package to Basler pylon Camera Software Suite
IP Configuration Tool to IP Configurator
pylon Viewer Tool to pylon Viewer
Made the appropriate changes throughout the manual to add the new
acA1280-60gm/gc, acA1300-22gm, acA1300-60gm/gm/gmNIR, acA1600-
60gm/gc, acA1920-25gm/gc, acA2000-50gm/gc - CMV2000-V3, acA2000-
50gmNIR - CMV2000-V3, acA2040-25gm/gc - CMV2000-V3, and
acA2040-25gmNIR - CMV4000-V3 camera models.
Corrected the pixel data format for the acA2500-14 camera model
throughout the manual (changed BG to GB).
Added LZ4 licensing information in Section 1.5.2 on page 37.
Removed absolute max. voltages from Table 11 on page 63, from Table 12
on page 67, from Section 5.7.2 on page 64, Table 12 on page 67, from
Section 5.8.2 on page 67.
Corrected the minimum operating voltage value to 10.8 V in Section 1.8 on
page 40 and in Section 5.5 on page 61.
Added information on the reverse X and reverse Y features in Section 8.1.1
on page 166.
Removed sub-section "Pixel Data Formats for Mono Cameras" in
Section 9.
To be continued.
Doc. ID Number Date Changes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler GigE SERIES and is the answer not in the manual?

Basler GigE SERIES Specifications

General IconGeneral
InterfaceGigE
Lens MountC-Mount, CS-Mount
SensorCMOS
MountC-mount, CS-mount
Power SupplyPower over Ethernet (PoE)
DimensionsVaries by model
WeightVaries by model
Operating TemperatureVaries by model

Related product manuals