Cube
®
Installation & Startup
10-4 Belanger, Inc. * PO BOX 5470. * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL963
Chapter 10 Undercarriage Option
Undercarriage In-Ground Connections
1) Locate the field supplied 3/4" black rubber water hose and two 3/4" hose clamps that were
provided with the Undercarriage Assembly.
2) Run the 3/4” water hose from the 3/4" barbed hose fitting to the Undercarriage Valve Assembly
located on the ICS Assembly and secure with the 3/4" Clamps. There are two different
Undercarriage Valve Assemblies either standard or rust inhibitor, as shown in the images below.
3) If you selected the Rust Inhibitor option, then the ICS Assembly will come with the Undercarriage
Rust Inhibitor Valve Assembly in place of the Standard Undercarriage Valve Assembly.
4) The Rust Inhibitor Valve has an Accessory Box that includes: Metering Tips with a Metering
Chart, additional Orifices #13 and #15, Strainer, Suction Tube Weight and 8’ of clear Suction
Tubing; as shown below.
Note: The 3/4” coupling and stainless-steel
barbed hose fitting are to be placed on
the same side as the Equipment Room.