Table of Functions
238
GM2 Series VFD
890054-00-00
Code
Comm.
Address
Name
Setting Range
Initial Value
Property*
V/F
SL
Ref.
2
User V/F
M2.26
0h1C1 A
Forward
Torque boost
0.015.0 (%)
2
X
O
O
p.134
M2.27
0h1C1B
Reverse
torque boost
0.015.0 (%)
X
O
O
p.134
M2.28
0h1C1C
Stall
prevention
level
30150 (%)
150
X
O
O
p.134
M2.29
0h1C1D
Electronic
thermal 1
minute rating
100200 (%)
150
X
O
O
p.134
M2.30
0h1C1E
Electronic
thermal
continuous
rating
50Electronic thermal 1
minute rating
100
X
O
O
p.134
M2.31
0h1C1F
Low-speed
torque
compensation
gain
50300 (%)
Varies by
Motor
capacity
X
X
O
-
M2.32
0h1C20
Stator
leakage
inductance
scale
50300 (%)
Varies by
Motor
capacity
X
X
O
-
M2.33
0h1C21
Stator
inductance
scale
50300 (%)
Varies by
Motor
capacity
X
X
O
-
M2.34
0h1C12
Rotor time
constant
scale
50300 (%)
Varies by
Motor
capacity
X
X
O
-
M2.40
0h1C28
Rotation
count speed
gain
0.16000.0[%]
100
O
O
O
-
M2.41
0h1C29
Rotation
count speed
scale
0
x 1
0: x 1
O
O
O
-
1
x 0.1
2
x 0.01
3
x 0.001
4
x 0.0001
M2.42
0h1C2A
Rotation
count speed
unit
0
Rpm
0: rpm
O
O
O
-
1
mpm
[1] Displayed when M2.08 is set to 4 (IM Sensorless).