Learning Basic Features
57
Lea
rni
890054-00-00
Set the Frequency Reference using V0, Built-in Potentiometer
You can modify the frequency reference using the built-in potentiometer. Set Frq
(Frequency reference source) to 4 (V0). View the frequency reference at the 0.00 (Main screen)
in the Operations group. Scaling of the V0 input is done with In.38 through In.41. View the
input voltage at In.35.
V0 Input Voltage Settings
Group
Code
Name
Setting
Setting Range
Unit
Operation
Frq
Frequency reference source
4
V0
08
-
In
01
Frequency for maximum analog
input
60.00
0Max Frequency
Hz
35
V0 input voltage display
0.00
0.005.00
V
37
Time constant of V0 input filter
100
010000
ms
38
V0 minimum input voltage
0.00
0.005.00
V
39
Output (%) at minimum voltage
0.00
0100
%
40
V0 maximum input voltage
5.00
0.005.00
V
41
Output (%) at maximum voltage
100.00
0.00100.00
%
46
Changing rotation direction of V0
0
No
01
-
47
V0 quantization level
0.04
0.00*, 0.0410.00
%
Setting the Reference Frequency using Input Current (I2)
You can modify the frequency reference using the I2 input terminal at the control board. Set Frq
(Frequency reference source) in the Operation group to 5 (I2) and apply 420 mA input current to
I2. Scaling of the input current range is done with In.53 through In.56. View the input current at
In.50.
Input Current (I2) Settings
Group
Code
Name
Setting
Setting Range
Unit
Operation
Frq
Frequency reference source
5
I2
08
-
In
01
Frequency for maximum analog
input
60.00
0Max Frequency
Hz
50
I2 input current display
0.00
0.0020.00
mA
52
Time constant of I2 input filter
100
010000
ms
53
I2 minimum input current
4.00
0.0020.00
mA
54
Output (%) at I2 minimum
current
0.00
0100
%
55
I2 maximum input current
20.00
0.0020.00
mA
56
Output (%) at I2 maximum
current
100.00
0.00100.00
%
61
Changing rotation direction of I2
0
No
01
-
62
I2 quantization level
0.04
0.00*, 0.0410.00
%
* Quantizing is disabled if "0" is selected.