Technical Specification
890054-00-00
262
GM2 Series VFD
Braking Resistor Specification
Inverter Capacity
Normal Duty
Heavy Duty
kW
HP
kW
HP
Resistance
(Ω)
Rated
Capacity
(W)
3-phase
240V
0.75
1
0.4
0.5
300
100
1.5
2
0.75
1
150
150
2.2
3
1.5
2
60
300
4
5
2.2
3
50
400
5.5
7.5
4
5
33
600
7.5
10
5.5
7.5
20
800
11
15
7.5
10
15
1,200
3-phase
480V
0.75
1
0.4
0.5
1,200
100
1.5
2
0.75
1
600
150
2.2
3
1.5
2
300
300
4
5
2.2
3
200
400
5.5
7.5
4
5
130
600
7.5
10
5.5
7.5
85
1,000
11
15
7.5
10
60
1,200
The standard for braking torque is 150% at a working rate of 5%
(%ED or duty cycle). If the ED% is increased to 10%, the rated
capacity (W) of the brake resistor must be doubled.
Related parameter Pr.66 (ED%)
Range 0 - 30%
Relay outputs OU.31 or OU.33 can be set to (31): DBWarn%ED
which toggles the relay when duty cycle is exceeded.