Learning Basic Features
63
Lea
rni
890054-00-00
Setting the Terminal Block as a Command Input Device - Run
and Rotation Direction Commands
Set parameter drv (command source) to 2 (Fx/Rx-2). This configuration (Fx/Rx-2) assigns the Fx
terminal as the Start/Stop input terminal and assigns the Rx terminal as the rotational direction
input terminal (Open: Fwd, Closed: Rev). Choose (2) of the digital input terminals (P1 ~ P5) to setup
as Forward and Reverse. Set (2) of the correspondinig parameters (In.65~In.69) to 1 (Fx) and 2 (Rx)
respectively.
Group
Code
Name
Setting
Setting Range
Unit
Operation
drv
Command Source
2
Fx/Rx-2
04
-
In
65~69
Px terminal setting
options
1
Fx
052
-
2
Rx
Run Command and Fwd/Rev Command Using Digital Input Terminals Setting
Details
Code and
Features
Description
drv Cmd Source
Set to 2 (Fx/Rx-2).
In.65 ~ 69
Px Define
Assign a terminal for run command (Fx).
Assign a terminal for changing rotation direction (Rx).