List Mode 55
5.3 List Run
List allows a sequence of outputs with up to 100 congurable steps. With sharable memory across all
three channels, a list can run simultaneously on various channels. This allows for a list to be compatible
in normal, parallel or series mode.
Before running a list its parameters must be congured.
1. Congure the parameters of each step. See 5.2
2. Set the settings of the channel which will output the list. See 5.1
a. Enable List State on desired channel.
b. Assign a List Number to the channel.
c. Select Pace {Dwell or Trigger}.
d. Select Trigger Source {Manual, Digital IO, or Remote }.
e. Select After List output {DC or Last}.
3. After conguring the list and channel parameters press to return to the main page.
– Vset will be replaced with List Start if List State was enabled.
Figure 5.7 List State Disabled
4. Select List start to start the list.
– Once the list begins List Start will change to Abort List
www.GlobalTestSupply.com