VC-6000
TM
Compact monitor Part B 1-channel input module for vibration velocity sensors
- 24 - C100584.002 Module Vers. 08 © VC-6000
TM
Compact monitor Nov. 2014
♦ DC-Signal path (DC coupled processing path)
This signal path has continuous access to the entire raw signal,
including the available DC voltage part of the signal.
In this path also the DC-operating point (sensor passive voltage)
resulting from the sensor power supply is acquired and monitored
(sensor OK-monitoring). An error-free measurement chain is
signalled through an OK LED on the front panel of the V-TIM.
♦ AC-path (AC coupled processing path)
This signal path has access only to the AC part of the raw sensor
signal. The dynamics of the processing can thus be used
completely for the vibration measurement. As a result the velocity
signal from a connected sensor can be evaluated with maximum
resolution and accuracy.
The input range of the AC signal path is continuously monitored for
signal over-ranging. When over-ranging of an A/D converter occurs
this is signalled by a red LED on the front of the V-TIM.
3.3 Technical data
3.3.1 Electrical properties
Input:
Input voltage range -21,5 V ... + 2,5 V
Frequency range of input signal > 0 ... ≥ 20 kHz
Input impedance 50 kΩ
Settling time ca. 45 s
Sensor Sensitivity step adjustable
Amplification in 8 steps from 1 ... 80
(6 0,75 %)
Buffered output:
Output voltage range min. -21 V ...+ 2 V
Frequency range of output signal > 0 ... > 10 kHz
Output load min. 10 kΩ
Amplification 1 (6 2 %)
Phase shift (8 Hz) 20 kHz < 15°
50 kHz < 35°
Phase shift (15 Hz) 20 kHz 180° + < 15°
50 kHz 180° + < 35°
Short-circuit proof Yes