1 689 989 087 2018-07-24| Robert Bosch GmbH
Initial startup | CRI/CRIN 848H | 71
en
4.6 Electrical connection of clamping
device
4.6.1 EPS 708
¶ Connect the trigger electronics by way of the con-
necting cable 1 684 463 698 (scope of delivery of
EPS 708) to connection X23 in the test area of the
EPS 708.
458847-36_P
Fig. 35: Connection of trigger electronics
4.6.2 EPS 815
1. Join connecting cable (Fig. 36, item1) 1 684 462 298
to X4 terminal of the control electronics.
2. Connect voltage supply cable (Fig. 36, item2)
1 684 463 504 to X2 terminal.
3. Connect voltage supply cable (Fig. 36, item3)
1 684 463 503 to X1 terminal.
458847-37_Pal
1
2
3
Fig. 36: Control electronics connection
1 RS 232 connecting cable
2 Voltage supply cable (-) 1 684 463 504
3 Voltage supply cable (+) 1 684 463 503