EasyManua.ls Logo

Bosch CRI 848H - Connecting Injectors Electrically (Passenger Vehicle)

Bosch CRI 848H
380 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 689 989 087 2018-07-24| Robert Bosch GmbH
Preparing for testing | CRI/CRIN 848H | 77
en
1.1
1.2
12
1
458847-06_Pal
2
3
6
5
7
4
1
1
1
A
A
Fig. 50: Connection diagram for passenger vehicle injectors on
EPS 815 (without high-pressure connection)
1 Hose line for injection quantity
2 Injection chamber
3 KMAmeasuring system
4 Injector
5 Hose line for return quantity
6 Hose line
1)
7 Heat exchanger
1)
Included in scope of delivery of heat exchanger.
5.2.6 Connecting injectors electrically
1. Select suitable adapter cable for actuation of the
injectors:
R For injectors with plug socket:
458806-20
Using adapter cable 1 684 463 506
SW
FD ...
1 684 463 506
A
B
C
D
E
F
458806-2
Fig. 51: Using adapter cable 1 684 463 506
R For injectors with plug socket:
458806-21
Using adapter cable 1 684 463 519
SW
FD...
1 684 463 519
458806-3
A
B
C
D
E
F
Fig. 52: Using adapter cable 1 684 463 519