EasyManua.ls Logo

Bosch CRI 848H - Connecting Return Adapter; Connecting Hose Lines for Quantity Measurement

Bosch CRI 848H
380 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 689 989 087 2018-07-24| Robert Bosch GmbH
76 | CRI/CRIN 848H | Preparing for testingen
6. Seal unused high-pressure outlets with sealing cone
(Fig. 47, item2) and union nuts (Fig. 47, item 1).
Tightening torque : 25 – 30 Nm
458847-25_Pal
1
25 - 30 Nm
2
Fig. 47: Plug for high-pressure outlet
5.2.4 Connecting return adapter
Insert return adapter (Fig. 48, item 2) into injector
return and secure in place using retaining ring
(Fig. 48, item1).
458847-23_Pal
2
1
Fig. 48: Injector with return adapter
5.2.5 Connecting hose line for return quantity and
injection quantity
! Pay attention to correct assignment of the measure-
ment channels when connecting the return quantity
and injected quantity hoses. A false assignment can
lead to wrong measurements and thus faulty assess-
ment of the injectors.
i The following connection diagram for the EPS 708
(Fig.49) or the EPS 815 (Fig.50) is based on injec-
tor "A" by way of example. The connection of addi-
tional injectors (B, C, D, E and F) is identical.
Connect the injector to the EPS 708 or EPS 815.
1
458847-19_Pal
1
1
2
4
5
6
3
A
B
1 2
A
A
Fig. 49: Connection diagram for passenger vehicle injectors on
EPS 708 (without high-pressure connection)
1 Hose line for injection quantity
2 Injection chamber
3 Injector
4 Hose line for return quantity
1)
5 EPS 708 injected quantity connection CRI/CRI piezo
6 EPS 708 return quantity connection CRI/CRI piezo
1)
Included in scope of delivery of EPS 708.