Installation Manual Output Programming
8-10
Bosch Security Systems 10/22 BLCC615I
53 – Keyfob Function 1
This event type will cause the output to operate when
Key X is pressed on the Keyfob. This output type is area
specific and requires a 4 button keyfob.
54 – Keyfob Function 2
This event type will cause the output to operate when
Key Y is pressed on the Keyfob. This output type is area
specific and requires a 4 button keyfob.
55 – Output In PreDelay
This event type will cause the output to operate when a
pre-delay timer is active on a different output set with a
polarity type of 01 (Normally Open, Going Low With Pre
Delay) or polarity type 08 (Normally Low, Going Open
With Pre Delay).
56 – Follow PIN Code
This event type will cause the output to operate when a
specified user PIN is entered via the keypad or when the
corresponding user’s keyfob or token is used.
You should program the user whose PIN is to be followed
into the Event Assignment for this output.
57 – Part Entry Time
This event type will cause the output to operate when
the Part Entry timer is active and will reset when Part
Entry time expires.
58 – TimeZones
This event type will cause the output to operate when
a timezone occurs. The output event assignment
programs which timezone to follow.
59 – Temperature Hi/Lo
This event type will cause the output to operate when
the keypad temperature increases above the maximum
or falls below the minimum set temperature. The output
will reset when the temperature reads between the
maximum and minimum values.
See MENU 7-7-3 — Keypad Hi/Lo Temp in Section 11 -
System Programming
60 – Door
This event type will cause the output to operate when a
user assigned to the same door swipes their token. The
prox reader must be assigned to the same door group as
the output and user.
The Event Assignment is the Door Assignment Number.
61 - Door Open Too Long
This output will turn on when the control panel has
detected that the zone assigned to the door has not
returned to normal before the end of the door open too
long time.
62 - Door Bell
This event type follows the door bell button on the
CP155B External Keypad.
69 - User Control
This event type allows users to control an output using
the iFob Control App.
70 - User Panic
The output will turn on when a user initiates a keyfob
panic emergency. The output will turn off when the area
has been turned All On or the output time parmeter has
finished.
71 - CLI Trigger
The output will turn on when the control panel has
detected an incoming call with a telephone number
programmed in Trigger Table 1 or Trigger Table 2.
72 - GSM Signal Lost
The output is triggered whenever the radio is
not registered on the GSM network and restores
automatically on exiting programming mode or when
the radio resumes its connection with the network.
73 - GPRS Failure
The output is triggered when communication to
the GPRS network is lost and data can no longer be
transferred between the radio and the APN (Access Point
Name). It restores automatically on exiting programming
mode or once data transmission resumes between the
radio and the APN.
74 - Ethernet Fail
The output will turn on when the control panel detects
that the ethernet cable has been unplugged from the
ethernet module. The output will turn off when the
control panel detects that the ethernet cable has been
restored for a period of at least 1 minute.
75 - Macro
This output will turn on when the assigned macro event
occurs. A macro can be set to follow a combination of
the following: output, area, macro, timezone, holiday,
zone and/or door. Set the output event assignment to
follow the macro (1 to 8) as required.