Continuing operating without entering a Department ID was attempted even though unknown-ID jobs
(functions that permit operations without a Department ID and PIN) were disabled in the Department ID
Management.
● Enable unknown-ID jobs in System Manager Mode in Remote UI.
Blocking Jobs When Department ID Is Unknown(P. 230)
#752
I-Fax receiving was impossible because an incorrect POP3 server name was set.
● Check the POP3 server name, and correct the setting.
Receiving I-Faxes for Printing(P. 194)
I-Fax receiving was impossible because an incorrect domain name was set.
● Check the domain name, and correct the setting.
Conguring DNS(P. 65)
I-Fax receiving was impossible because the machine was not connected to a network correctly.
● Check whether the machine is properly installed and correctly connected to the network.
Installation/Settings Problems(P. 452)
#753
Scanned data could not be received as I-Fax because the LAN cable is disconnected.
● Check whether the LAN cable is connected correctly.
Connecting to a Wired LAN(P. 26)
#766
The certicate has expired.
● Update the certicate or use a certicate that has not expired.
● Check that the <Current Date/Time Settings> are correct.
Setting the Date/Time(P. 21)
#802
The POP3 server name is not set correctly.
● Set the POP3 server name correctly.
Receiving I-Faxes for Printing(P. 194)
Troubleshooting