Model 201 Installation & Technical
8400-M117-O1 Rev D
(Ouput Timer)
This setting is used for the 1 speed timed mode of operation and controls
how long the filling output is activated in milliseconds.
Press the F3/ key to show the current setting. If the setting displayed
is acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ and F1/ keys to enter a new setting and then press the F3/ key
to save it.
doUT= (Discharge Output)
This is the output that is driven when discharging is occurring. This is a
binary field to allow for driving of more than one output during this stage of
the filling cycle. For more information see the 11.2 Output Assigning
section.
(Trim)
This setting controls the trim value of the filling process. This is the
amount of weight below the actual target value at which the output will be
deactivated in order to accurately arrive at the target weight.
Press the F3/ key to show the current setting. If the setting displayed
is acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ and F1/ keys to enter a new setting and then press the F3/ key
to save it.
(Zero Tolerance)
If , the completed fill operation will immediately discharge. The
discharge will continue until the scale weight returns to zero within the
(Zero Tolerance) value.
Press the F3/ key to show the current setting. If the setting displayed
is acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ and F1/ keys to enter a new setting and then press the F3/ key
to save it.