CESSNA SECTION 2
MODEL 2088 (675 SHP) LIMITATIONS
MISCELLANEOUS INSTRUMENT MARKINGS
Power plant instrument markings and their color significance are shown
in Figure
2-5.
INSTRUMENT
Fuel Quantity
Indicators (I)
Fuel Quantity
Indicators (2)
Suction Gage (3)
To 15,000 Ft
To 20,000 Ft
To 25,000 Ft
I
Figure 2-5. Miscellaneous Instrument Markings
RED
LlNE
(Minimum
Limit)
E
(2.5 Gal
Unusable
Each Tank)
E
(2.8
Gal
Unusable
Each Tank)
- - -
Propeller
Anti-Ice
Ammeter
I
I I
I
1. SIN 20880001 thru 20880089 not modified with Service Kit
SK208-52:
Total unusable when operating with both tanks ON is 3.0 U.S. gallons.
2. SIN 20880001 thru 20880089 modified with Service Kit
SK208-
52, and SIN 20880090 and ON:
Total unusable when operating with both tanks ON is 3.6 U.S. gallons.
~,
3. Incorporates stepped green arc with 15K, 20K, 25K and 30K
markings at the appropriate step locations to indicate the altitude
(in thousands of feet) at which the lower limit of that arc segment
is acceptable.
Oxygen Pressure
Gage
FAA APPROVED
1
Revision 23
+
GREEN ARC
(Normal
Operating)
- - -
-
-.
4.5-5.5 in.Hg
4.0-5.5 in.Hg
3.5-5.5 in.Hg
- - -
U.S. 2-1
1
- - -
YELLOW
ARC
(Caution
Range)
---
-.
-
---
20-24 Amps
RED
LlNE
(Maximum
Limit)
---
---
---
1550-1850
PSI
---
.
- -
0-300 PSI 2000 PSI