CESSNA
MODEL
2088 (675 SHP)
SMOKE
AND
FlRE
(Continued)
SECTION
3
EMERGENCY PROCEDURES
ENGINE FlRE DURING START ON GROUND (Red ENGINE
FlRE
Annunciator
ON
or
OFF)
1.
Fuel Condition Lever
-
CUTOFF.
2.
Fuel Boost Switch
-
OFF.
3.
Starter Switch
-
MOTOR.
CAUTION
DO NOT EXCEED THE STARTING CYCLE
LIMITATIONS; REFER TO SECTION 2.
SHOULD THE FlRE PERSIST, AS INDICATED BY
SUSTAINED
INTERSTAGE TURBINE
TEMPERATURE, IMMEDIATELY CLOSE THE FUEL
SHUTOFF AND CONTINUE MOTORING.
(Continued Next Page)
4.
Starter Switch
-
OFF.
5. Fuel Shutoff
-
OFF (pull out).
6.
Battery Switch
-
OFF.
7. Airplane
-
EVACUATE.
8. Fire
-
EXTINGUISH.
ICING
THE FOLLOWING WEATHER CONDITIONS MAY BE CONDUCIVE
TO SEVERE IN-FLIGHT
ICING
-
As Required
by
AD
96-09-15,
Paragraph
(a)
(2):
1. Visible rain at temperatures below
0
degrees Celsius ambient air
temperature.
2. Droplets that splash or splatter on impact at temperatures below
0 degrees Celsius ambient air temperature.
r,
~~,
-,
=,
.
=,
.--,
*-,
.~
~~,
-,
-1
~
3
-,
~~,
1
Revision 23
*
--,
(Continued Next Page)
U.S. 3-15