CE Declaration of Conformity
670 Check Point UTM-1 Edge User Guide
IEC 61000-4-2 Electrostatic Discharge
(ESD)
8 kV Air Discharge, 4 kV Contact Discharge
Performance Criterion B
IEC 61000-4-3 Radiated, radio-
frequency,
electromagnetic field
immunity
80-1000 MHz, 3 V/m, 80% AM (1 kHz)
Performance Criterion A
IEC 61000-4-4 Electrical fast transient /
burst immunity
AC Power Line: 1 kV
DC Power Line: 0.5 kV
Signal Line: 0.5 kV
Performance Criterion B
IEC 61000-4-5 Surge immunity 1.2/50 us Open Circuit Voltage, 8/20 us
Short Circuit Current
AC Power Line: line to line 1 kV, line to earth
2 kV
DC Power Line: line to earth 0.5 kV
Signal Line: 1 kV
Performance Criterion B
IEC 61000-4-6 Immunity to conducted
disturbances, induced by
radio-frequency fields
0.15-80 MHz, 3 Vrms, 80% AM, 1 kHz
Performance Criterion A
IEC 61000-4-8
Power frequency
magnetic field immunity
50 Hz, 1 A/m
Performance Criterion A