2-558
Catalyst 3750-X and 3560-X Switch Command Reference
OL-21522-02
Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands
show diagnostic
This example shows how to display the detailed switch results for all the switches in stack. You can also
use the show diagnostic result switch all detail command to display these results.
Switch> show diagnostic switch all detail
Switch 1: SerialNo : CAT1007R044
Overall diagnostic result: PASS
Test results: (. = Pass, F = Fail, U = Untested)
___________________________________________________________________________
1) TestPortAsicStackPortLoopback ---> .
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 19
Last test execution time ----> Mar 01 1993 00:21:46
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> Mar 01 1993 00:21:46
Total failure count ---------> 0
Consecutive failure count ---> 0
___________________________________________________________________________
2) TestPortAsicLoopback ------------> U
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 0
Last test execution time ----> n/a
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> n/a
Total failure count ---------> 0
Consecutive failure count ---> 0
___________________________________________________________________________
3) TestPortAsicCam -----------------> U
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 0
Last test execution time ----> n/a
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> n/a
Total failure count ---------> 0
Consecutive failure count ---> 0
___________________________________________________________________________
4) TestPortAsicRingLoopback --------> U
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 0
Last test execution time ----> n/a
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> n/a
Total failure count ---------> 0
Consecutive failure count ---> 0
___________________________________________________________________________
5) TestMicRingLoopback -------------> U
Error code ------------------> 0 (DIAG_SUCCESS)

Table of Contents

Other manuals for Cisco Catalyst 3560X-24P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3560X-24P and is the answer not in the manual?

Cisco Catalyst 3560X-24P Specifications

General IconGeneral
BrandCisco
ModelCatalyst 3560X-24P
CategorySwitch
LanguageEnglish

Related product manuals