EasyManuals Logo

Cisco D9824 User Manual

Cisco D9824
416 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #240 background imageLoading...
Page #240 background image
Chapter 5 Web GUI Setup and Monitoring
218
PSI Rate
Description
Auto
Matches the generated PSI tables' output rate to the incoming rate.
MPEG Min
Transmits the generated PSI tables on the longest intervals that are
allowed by MPEG standard.
SA Std
Transmits the generated PSI tables based on PowerVu standard
intervals.
7 From the PSI Table Output Option drop-down list, choose the action to perform
on the PSI tables for the output stream. The following table describes each
option:
PSI Options
Description
Pass All
Transmits the incoming PSI Tables as is; does not modify the
content and rate. The SI Regeneration Option and table settings are
ignored.
Drop All
Does not transmit any PSI Tables. The SI Regeneration Option and
table settings are ignored.
Ctl By Table
The operator can click Table Options to select the table specific
output mode for each table.
8 If Ctl By Table is selected as the PSI Table Output Option, click Table Options
to configure the DPM table options. The DPM Table Options (ASI) window is
displayed.
Choose the tables which will be passed, dropped, regenerated or passed with
rate control (PwRC) from the ASI Output. For more information on the table
options, see PSI Table Settings (on page 117).