Chapter 6 Service and Maintenance
318
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
Decoder
Processor Start
Clear
Boot passed
Major
38000
LEC Timeout
Set
LEC Table
Missing/timeout:c
hannels currently
unavailable
Cause: Possible
LEC Server or
Uplink issue.
Remedy: Check
LEC Server setup
and uplink
configuration for
the GDS PID
setup. Clear alarm
and notify Cisco
Services if the
problem persists.
ECT Table is
not received in
the GDS
stream.
Major
38500
LEC Timeout
Clear
LEC received
Major
38500
FPGA status
Set
FPGA Init failed to
go high
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, notify Cisco
Services if the
problem persists.
FPGA setup
failure or the
FPGA binary
identity does
not match the
FPGA registers.
Major
39000
FPGA status
Set
FPGA Init and
Done failed to go
low
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, notify Cisco
Services if the
problem persists.
FPGA setup
failure or the
FPGA binary
identity does
not match the
FPGA registers.
Major
39000
FPGA status
Set
FPGA Init went
LOW (CRC error)
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, notify Cisco
Services if the
problem persists.
FPGA setup
failure or the
FPGA binary
identity does
not match the
FPGA registers.
Major
39000

Table of Contents