Configuring Transport Stream Information
6 From the SI Regeneration Option drop-down list, choose the SI regeneration
option that applies the PowerVu rates (consistent with the uplink). This
parameter is only used if Remapping Control is set to None. The following table
describes each PSI rate:
Matches the generated PSI tables' output rate as the incoming rate.
Transmits the generated PSI tables on the longest intervals that are
allowed by MPEG standard.
Transmits the generated PSI tables based on PowerVu standard
intervals.
7 From the PSI Table Output Option drop-down list, choose which PSI tables to
include in the program/output stream. The following table describes each
option:
Transmits the incoming PSI Tables as is; does not modify the
content and rate.
Does not transmit any PSI Tables.
The operator can click Table Options to select the output mode
for each table. The default table selections will be all pass, and
only with CDT dropped.
8 From the PSI Regeneration Option drop-down list, choose whether to
regenerate the PSI tables. You can select Always or As Needed (only if the
content has changed).