EasyManua.ls Logo

Cisco D9858 - Page 303

Cisco D9858
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
281
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
PE n: Loss of
Input
Clear
Fault reset
Minor
11000
12000
13000
14000
15000
16000
17000
18000
18009-18032
Digital Program
Mapping
Set
PID Collision
Cause: Uplink
settings may have
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink to
find the
appropriate system
settings.
Two source
service PIDs
are being
mapped to the
same output
PID. This will
cause data
corruption in
the stream.
Minor
19000
Digital Program
Mapping
Set
Program Collision
Cause: Uplink
settings may have
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink to
find the
appropriate system
settings.
Two source
channel
numbers are
being
mapped/
passed to the
same channel
number in the
output.
Minor
19000
Digital Program
Mapping
Set
Mode-i PMT out of
range
Cause: Uplink
settings may have
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink to
find the
appropriate system
settings.
PMT PID to be
used for
Mode-i is
outside of
valid MPEG
PID range.
Major
19000

Table of Contents

Related product manuals