DETAILED STEPS
Complete the Clear a Lock-On or Lockout Command, on page 447 procedure.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
LOF (BITS)
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: BITS
The Loss of Frame (LOF) BITS alarm occurs when a port on the control card BITS input detects an LOF on
the incoming BITS timing reference signal. LOF indicates that the receiving ONS system has lost frame
delineation in the incoming data.
The procedure assumes that the BITS timing reference signal is functioning properly. It also assumes the
alarm is not appearing during node turn-up.
Note
Clear the LOF (BITS) Alarm
SUMMARY STEPS
1. Verify that the line framing and line coding match between the BITS input and the control card :
2. If the alarm does not clear when the line framing and line coding match between the BITS input and the
control card, complete the Physically Replace a Card, on page 453 procedure for the control card.
DETAILED STEPS
Step 1 Verify that the line framing and line coding match between the BITS input and the control card :
a) In node or card view, note the slot and port reporting the alarm.
b) Find the coding and framing formats of the external BITS timing source. The formats should be in the user
documentation for the external BITS timing source or on the timing source itself.
c) In node view (single-shelf mode) or shelf view (multishelf mode), click the Provisioning > Timing > BITS Facilities
tabs.
d) Verify that the Coding setting matches the coding of the BITS timing source, either B8ZS or AMI.
e) If the coding does not match, click Coding and choose the appropriate coding from the drop-down list.
f) Verify that Framing matches the framing of the BITS timing source, either ESF or SF (D4).
g) If the framing does not match, click Framing and choose the appropriate framing from the drop-down list.
On the timing subtab, the B8ZS coding field is normally paired with ESF in the Framing field and the AMI
coding field is normally paired with SF (D4) in the Framing field.
Note
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
264
Alarm Troubleshooting
LOF (BITS)

Table of Contents

Other manuals for Cisco NCS 2000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2000 series and is the answer not in the manual?

Cisco NCS 2000 series Specifications

General IconGeneral
BrandCisco
ModelNCS 2000 series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals