DETAILED STEPS
Complete the Clear the PWR-FAIL-A Alarm, on page 368 procedure.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
PWR-FAIL-RET-B
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Equipment Power Failure at Connector B alarm occurs when there is no power supplied to the backup
power connector on the shelf. This alarm occurs on the electrical interface assemblies (EIA) or the control
card.
Clear the PWR-FAIL-RET-A Alarm
SUMMARY STEPS
1. Complete the Clear the PWR-FAIL-A Alarm, on page 368 procedure.
DETAILED STEPS
Complete the Clear the PWR-FAIL-A Alarm, on page 368 procedure.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
PWR-PROT-ON
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Objects: OTS
The Raman Power Protection On alarm occurs only on the OPT-RAMP-C, OPT-RAMP-CE, EDRA-1-xx,
EDRA-2-xx, and RAMAN CTP cards when the Raman amplifier is used on fiber span that is too short for
Raman power.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
370
Alarm Troubleshooting
PWR-FAIL-RET-B

Table of Contents

Other manuals for Cisco NCS 2000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2000 series and is the answer not in the manual?

Cisco NCS 2000 series Specifications

General IconGeneral
BrandCisco
ModelNCS 2000 series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals