If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
MS-DEG
Default Severity:Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: STM1E
The Multiplex Section Signal Degrade condition is similar to the SDBER-EXCEED-HO , on page 388 alarm,
but applies only to the multiplex section overhead of the EQPT object.
Clear the MS-DEG Condition
SUMMARY STEPS
1. Complete the Clear the SDBER-EXCEED-HO Condition, on page 389 procedure.
DETAILED STEPS
Complete the Clear the SDBER-EXCEED-HO Condition, on page 389 procedure.
If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
MS-EOC
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: STMN
The MS-DCC Termination Failure alarm occurs when the system loses its data communications channel. The
DCC is nine bytes, D4 through D 12, in the SONET overhead. The bytes convey information about Operation,
Administration, Maintenance, and Provisioning (OAM&P). The system uses the DCC on the SONET section
overhead to communicate network management information.
Clear the MS-EOC Alarm
SUMMARY STEPS
1. Complete the Clear the RS-EOC Alarm, on page 381 procedure.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
307
Alarm Troubleshooting
MS-DEG