D15335.02 Cisco TelePresence MX700 and MX800 API Reference Guide CE8.0, FEBRUARY 2016.
Copyright © 2016 Cisco Systems, Inc. All rights reserved. 18
Cisco TelePresence MX700 and MX800
API Reference Guide
API fundamentals
This chapter contains a top-level view of the mechanisms
supported by the codec API.
Here you can read about how to access the API, how to use
the command line and what the different parts of the API
can be used for. This chapter also describes how to use the
feedback functions that are available for the codec.
The API consists of four major groups:
Commands
Configurations
Status
Events
These four groups are hierarchically organized, which
makes it easier to find related functionality. You can find the
complete lists of all commands, configurations and statuses
in the following chapters.
Connecting to the API
There are several ways to access the codec API. Regardless
of which method you choose, the structure of the API stays
the same. Choose the connection method that suites your
application best. Before you start, please read this section
about the different methods, as some of those may require
additional configuration changes before being enabled.
The following configurations, appart from password, can be
set from the System configuration menu on the web interface
or from the command line interface. All of the examples are
for the command line interface.
Password
The video system is delivered with a default user account
with full credentials. The user name is admin, and initially, no
password is set for the default user.
It is mandatory to set a password for the admin user in
order to restrict access to system configuration. You should
in addition set a password for any other user with similar
credentials.
You can set the password on the codec’s web interface.
Open a web browser and enter the IP address of the video
system in the address bar and log in. Click your user name in
the upper right corner and choose Change password in the
drop down menu.
RS-232/serial connection
This is one of the most used connections to our products for
integrators, as it can be used without an IP address, DNS or
a network.
Codec configurations
There are two different configurations that can be changed
for serial connections; the baud-rate and whether login is
required or not.
xConfiguration SerialPort BaudRate:
<9600/19200/38400/57600/115200>
xConfiguration SerialPort LoginRequired: <Off/On>
Connecting
Note:
For security reasons the password prompting is turned
on by default, but it can be turned off if preferred.
The default baud rate is set to. The codec can give very
much feedback. We therefore recommend keeping the
connection at this speed.
Introduction
About the API
xConfiguration
Appendices
xCommand
xStatus
About the API

Table of Contents

Other manuals for Cisco Telepresence MX800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Telepresence MX800 and is the answer not in the manual?

Cisco Telepresence MX800 Specifications

General IconGeneral
Pan range-90 - 60 °
Product typeVideo conferencing service management system
Product colorWhite
Wall mountableYes
Tilt angle range-14 - 12 °
Number of persons- person(s)
Aspect ratio16:9
Maximum frame rate60 fps
Supported video modes720p, 1080p
Video formats supportedH.261, H.263, H.264, H.265
Resolution at capture speed1920x1080@60fps
Supported graphics resolutions352 x 288, 512 x 288, 1024 x 576 (WSVGA), 1024 x 768 (XGA), 1280 x 720 (HD 720), 1280 x 768 (WXGA), 1920 x 1080 (HD 1080), 1920 x 1200 (WUXGA)
Megapixel- MP
Sensor type-
Digital zoom2 x
Optical zoom10 x
Image sensor size- \
Closest focusing distance1 m
Ethernet LAN data rates10, 100, 1000 Mbit/s
Display diagonal70 \
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)10 - 90 %
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (max)591 W
Power consumption (typical)571 W