InteliDrive DCU Industrial 3.4.0 Global Guide
139
Setpoint group Load sharing Related FW 3.4.0
Range [units] 0.0 .. ClutchMaxSpeed [%]
Default value 0.0
Force value
Alternative config
Step 0.1
Comm object 10096 Related applications AS
Description
Clutch can be switched on if ClutchMinSpeed < RPM < ClutchMaxSpeed. Limits are in % of the
Requested speed. See Function description details (page 63)
Note: 0.0% corresponds to (Idle speed + Idle offset) value, 100.0% corresponds to Nominal speed.
ClutchMinSpeed
6 back to List of setpoints
Setpoint group Load sharing Related FW 3.4.0
Range [units] ClutchMinSpeed .. 100.0 [%]
Default value 100.0
Force value
Alternative config
Step 0.1
Comm object 10097 Related applications AS
Description
Clutch can be switched on if ClutchMinSpeed < RPM < ClutchMaxSpeed. Limits are in % of Requested
speed. See Function description details (page 63).
Note: 0.0% corresponds to (Idle speed + Idle offset) value, 100.0% corresponds to Nominal speed.
ClutchMaxSpeed
6 back to List of setpoints