Table A.3: P0 Utility Connector Pin Assignments
Wafer
No.
Row G
Signal
Row F
Signal
Row E
Signal
Row D
Signal
Row C
Signal
Row B
Signal
Row A
Signal
1 Vs1_BP12V Vs1_BP12V Vs1_BP12V NC Vs2_BP12V Vs2_BP12V Vs2_BP12V
2 Vs1_BP12V Vs1_BP12V Vs1_BP12V NC Vs2_BP12V Vs2_BP12V Vs2_BP12V
3 Vs3_NC_BP_5V Vs3_NC_BP_5V Vs3_NC_BP_5V NC Vs3_NC_BP_5V Vs3_NC_BP_5V Vs3_NC_BP_5V
4 SM2_BP_I2C1_SCL SM3_BP_I2C1_DAT GND -12V_AUX GND SYSRST_L NVMRO
5 GAP_L GA4_L GND 3.3V_AUX GND SM0_BP_I2C0_SCL SM1_BP_I2C0_DAT
6 GA3_L GA2_L GND +12V_AUX GND GA1_L GA0_L
7 TCK GND TDO TDI GND TMS TRST_L
8 GND REF_CLK_N REF_CLK_P GND BP_AUX_CLK_N BP_AUX_CLK_P GND
Table A.4: P0 Utility Connector Signal Definitions
CHAMP-AV8 Signal Description
Vs1_BP12V +12V Power; 12V ± 5%, Max Nominal Ripple ≤ 240 mV, up to 24 A - Vs1
Vs2_BP12V +12V Power; 12V ± 5%, Max Nominal Ripple ≤ 240 mV, up to 24 A - Vs2
Vs3_NC_BP_5V No Connect - Vs3
3.3V_AUX +3.3V Auxiliary Power; 3.3V±5%, Nominal Ripple ≤ 30 mV; 1 A max
+12V_AUX +12V Power; 12V ± 5%, Nominal Ripple ≤ 50 mV; 1 A max
-12V_AUX -12V Power; -12V ± 5%, Nominal Ripple ≤ 50 mV; 1 A max
GA4_L:GA0_L; GAP_L Geographical Address Inputs 0-4 and Parity; Must pull-up to 3.3V on-board.
NVMRO Non-Volatile Memory Read Only - Active high signal that prevents any non-volatile memory from being
updated; pulled-up to 3.3VAUX on backplane; can only be driven low by backplane.
Note: this signal does not write-enable the PABS (Permanent Alternate Boot Select) Flash memory.
REF_CLK_P
REF_CLK_N
Differential bussed reference clock; 25 MHz ±100 ppm; 45% to 55% duty cycle; M-LVDS signaling; rise and
fall time > 1 ns; driven by SYS_CON.
SYSRST_L System Reset; pulled-up to 3.3VAUX on backplane; usually driven by SYSCON but can be driven by any
board in the system.
TCLK, TDO, TDI, TMS, TRST_L JTAG Signals; TCLK, TDO, and TDI are pulled-up to 3.3V on-board; TRST_L is pulled-down.
BP_AUX_CLK_P
BP_AUX_CLK_N
Differential bussed reference clock; 1 Hz +50 ppm; minimum pulse width of 100 µs; LVDS signaling; rise and
fall time ≥ 1 ns; driven by SYS_CON.
SM0_BP_I2C0_SCL,
SM1_BP_I2C0_DAT
System management I
2
C bus number 1.
SM2_BP_I2C1_SCL,
SM3_BP_I2C1_DAT
System management I
2
C bus number 2.
NC No connect.
GND Ground signals as defined in VITA 46.0.