EasyManua.ls Logo

D-Link DFL-260E

D-Link DFL-260E
486 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.29.29. bad_lsa_sequencenumber (ID: 02400108)
Default Severity
WARNING
Log Message
Got LSA with bad sequence number <seqnum>. Restarting exchange
Explanation
Received a LSA with a bad sequence number.
Gateway Action
restart
Recommended Action
None.
Revision
1
Parameters
seqnum
Context Parameters
Rule Name
2.29.30. bad_lsa_maxage (ID: 02400109)
Default Severity
WARNING
Log Message
Got LSA with bad maxage (<maxage> > <def_maxage>). Restarting
exchange
Explanation
Received a LSA with a bad maxage value.
Gateway Action
restart
Recommended Action
Check orginating router configuration.
Revision
1
Parameters
maxage
def_maxage
Context Parameters
Rule Name
2.29.31. lsa_checksum_mismatch (ID: 02400150)
Default Severity
WARNING
Log Message
LSA checksum mismatch. LSA is discarded
Explanation
Received LSA with mismatching checksum.
Gateway Action
discard
Recommended Action
Check network equipment for problems.
Revision
1
Context Parameters
Rule Name
2.29.32. unknown_lsa_type (ID: 02400151)
2.29.29. bad_lsa_sequencenumber
(ID: 02400108)
Chapter 2. Log Message Reference
352

Table of Contents

Other manuals for D-Link DFL-260E