2.46. TIMESYNC
These log messages refer to the TIMESYNC (Firewall time synchronization events) category.
2.46.1. synced_clock (ID: 03500001)
Default Severity
NOTICE
Log Message
The clock at <oldtime>, was off by <clockdrift> second(s) and
synchronized with <timeserver> to <newtime>
Explanation
The clock has been synchronized with the time server.
Gateway Action
None
Recommended Action
None.
Revision
2
Parameters
oldtime
newtime
clockdrift
timeserver
2.46.2. failure_communicate_with_timeservers (ID:
03500002)
Default Severity
WARNING
Log Message
Communication with the timeserver(s) failed. Clock not updated.
Explanation
The unit failed to establish a connection with the time sync server. The
clock has not been updated.
Gateway Action
clock_not_synced
Recommended Action
Verify that the time sync server is running.
Revision
1
2.46.3. clockdrift_too_high (ID: 03500003)
Default Severity
WARNING
Log Message
According to the timeserver the clock has drifted <clockdrift>
seconds(s) which is NOT in the allowed correction interval
(+/-<interval> seconds)
Explanation
The clock has drifted so much that it is not within the allowed +/-
correction interval. The clock will not be updated.
Gateway Action
clock_not_synced
Recommended Action
If the correction interval is too narrow, it can be changed in the
Advanced Settings section.
2.46. TIMESYNC Chapter 2. Log Message Reference