Preventing Operational Faults due to ESD
Camera installations which do not protect against ESD (electrostatic discharge)
may exhibit operational faults. Problems such as random data loss, random
camera resets and other non-reoccurring control issues may all be solved by
proper ESD management.
Teledyne DALSA has performed ESD testing on cameras using an 8 kilovolt ESD generator without
any indication of operational faults.
To help prevent ESD problems, mount the camera on a metallic platform with a good connection to
earth ground.