STANDARD OBJECTS
PRODUCT REFERENCE GUIDE
110
STANDARD OBJECTS
Identity Object (01HEX - 1 Instance)
Class Attributes
Instance Attributes
Status Word
Common Services
Reset Service Code
Attribute ID Name Data Type Data Value Access Rule
1 Revision UINT 1 Get
Attribute ID Name Data Type Data Value Access Rule
1 Vendor Number UINT 25DEC Get
2
Device Type
0x00 – Generic
UINT 00HEX Get
3 Product Code Number UINT 01 Get
4
Product Major Revi-
sion
Product Minor Revi-
sion
USINT
USINT
03
01
Get
5
Status Word (see
below for definition)
WORD See Below Get
6
Product Serial Num-
ber
UDINT
Unique
32 Bit Value
Get
7
Product Name
Structure of:
Product Name Size
Product Name String
UINT
USINT[0-32]
15
“Bar Code
Reader”
Get
Bit Bit = 0 Bit = 1
0 No I/O Connection I/O Connection Allocated
1 – 15 Unused Unused
Service Code Implemented for Service Name
Class Level Instance Level
0EHEX Yes Yes
Get_Attribute_Sin-
gle
05HEX No Yes Reset
Service Class Instance Attribute Description
Code
05HEX 1 1 0 Force software reset
05HEX 1 1 1
Reload factory settings and
reset