TRIGGER AND FOCUSING DEVICE WIRING
PRODUCT REFERENCE GUIDE
56
Digital Output Configuration for CBX100
The CBX100 includes an OUTPUTS block for wiring relays as needed for external acces-
sories. e-Genius Modify | Relays window includes options for outputs 1 and 2 including
Life Light, Trigger Output, Error Light, Ready Light, Good Dim, and No Dim.
Schematics for Isolated and Non-Isolated relays are provided below.
Unpowered Outputs
Powered Outputs
Outputs 1 and 2
Maximum Voltage 30V
Collector Current (pulse) 130 mA Max.
Collector Current (continuous) 40 mA Max.
Saturation Voltage (VCE) 1 V at 10 mA Max.
Max Power Dissipation 90 mW at 50 degrees C
(Ambient temperature)