TOTAL- ACEXTREME® SIGNALS
Data Device Corporation DS-BU-67301B-G
www.ddc-web.com
1/14
118
Table 21. Miscellaneous Signals
Signal Name BALL Pullup/
Pulldown
Description
nMCRST/nINCMD (O) L12 N/A Mode Code Reset or In-command.
The function of this pin is controlled by bit 19 of “RT_GCFG” (RT Global
Configuration) register.
When RT_GCFG = ‘0’, nMCRST / nINCMD functions as nINCMD.
nINCMD is asserted low to frame the time that a message is being processed
by the Total-AceXtreme.
When RT_GCFG = ‘1’, - nMCRST / nINCMD functions as nMCRST.
In RT mode, nMCRST is asserted low for two CLOCK_IN clock cycles (50 ns)
following receipt of a Reset remote terminal mode command.
In BC-only or Monitor-only modes, this signal is inoperative; i.e., in this case, it
will always output a value of logic ‘1’.
In addition, nMCRST/nINCMD will also assert low during the time that the
Total-AceXtreme is performing its logic self-test. Therefore, nMCRST/nINCMD
can be monitored to determine when this self-test has been completed.
DISABLE_BIST (I) C13 50k
Pulldown
If this input is set to logic ‘0’, the Built-In-Self-Test (BIST) will be enabled after
hardware reset (for example, following the low-to-high transition of nPOR
following power-up). A logic ‘1’ input disables both the power-up and user-
initiated automatic BIST.
TX_INH_A (I) P13 50k Pullup Transmitter inhibit inputs for Channel A and Channel B, MIL-STD-1553
transmitters. For normal operation, these inputs should be connected to logic
‘0’. To force a shutdown of Channel A and/or Channel B, a value of logic ‘1
should be applied to the respective TX_INH input.
TX_INH_B (I) P14 50k Pullup
IRIG_DIG_IN (I) N14 50k Pullup Digital IRIG-B time code input supporting 48-bit time-tags.
Digital IRIG data is read once per second.
IRIG Time can be used as the Time-Tag instead of the local timer.
nINT (O) P2
50k Pullup
Interrupt Request output.
The operation of nINT is programmable by means of the CPU Interrupt Pin
Control R
egister. This register is only accessible via the CPU Interface, not the
PCI interface. The user-programmable parameters for nINT include:
(1) Open-drain or TTL output
(2) Active high or low
(3) Pulse or level
(4) For the case of a pulse interrupt, the pulse width is programmable. The
pulse width may be programmed for a value between 3 and 65,537 clock
cycles. The clock used for formulating the nINT pulse width will be the
Total-AceXtreme’s internal 160 MHz clock for the Asynchronous CPU
interface mode, and the HOST_CLK for the Synchronous CPU interface
mode.
CLOCK_IN (I) A8 None 40 MHz clock input (MIL-STD-1553 bus clock)