TOTAL- ACEXTREME® SIGNALS
Data Device Corporation DS-BU-67301B-G
www.ddc-web.com
1/14
120
Table 22. Additional Connections & Interface to External Transceiver
Signal Name
Utilizing Internal
“Built-In
Transceivers
BALL
Pullup/
Pulldown
For Use With External Transceivers
“Transceiverless Mode”
nSINGEND(I) Connect to
+3.3V_LOGIC or
leave floating if
using built-in
transceivers.
R13 50k Pullup If nSINGEND is connected to logic ’0‘, the Manchester
decoder inputs will be configured to accept single-
ended input signals (e.g., MIL-STD-1773 fiber optic
receiver outputs). Refer to paragraph 8.2 for use of the
single-ended input mode to interface with a fiber optic
transceiver.
If nSINGEND is connected to logic ’1‘, the decoder
inputs will be configured to accept standard double-
ended Manchester bi-phase input signals; i.e., MIL-
STD-1553 receiver outputs.
TXDATA_OUT_A (O) These two signals
MUST be directly
connected for
normal “Built-In
transceiver
operation.
J10
N/A
These two signals MUST be separated for
“Transceiverless” operation.
Digital Manchester bi-phase transmit data outputs.
Connect directly to corresponding inputs of a MIL-
STD-1553 or MIL-STD-1773 (fiber optic) transceiver.
TXDATA_IN_A (I) K10
50k
Pulldown
TXDATA_OUT_A_L (O) These two signals
MUST be directly
connected for
normal “Built-In
transceiver
operation.
J11
N/A
These two signals MUST be separated for
“Transceiverless” operation.
Digital Manchester bi-phase transmit data outputs.
Connect directly to corresponding inputs of a MIL-
STD-1553 or MIL-STD-1773 (fiber optic) transceiver.
TXDATA_IN_A_L (I) K11
50k
Pulldown
TXDATA_OUT_B (O) These two signals
MUST be directly
connected for
normal “Built-In
transceiver
operation.
L10
N/A
These two signals MUST be separated for
“Transceiverless” operation.
Digital Manchester bi-phase transmit data outputs.
Connect directly to corresponding inputs of a MIL-
STD-1553 or MIL-STD-1773 (fiber optic) transceiver.
TXDATA_IN_B (I) M10
50k
Pulldown
TXDATA_OUT_B_L (O) These two signals
MUST be directly
connected for
normal “Built-In
transceiver
operation.
L9
N/A
These two signals MUST be separated for
“Transceiverless” operation.
Digital Manchester bi-phase transmit data outputs.
Connect directly to corresponding inputs of a MIL-
STD-1553 or MIL-STD-1773 (fiber optic) transceiver.
TXDATA_IN_B_L (I) M9
50k
Pulldown
TXINH_OUT_A (O) These two signals
MUST be directly
connected for
normal “Built-In
transceiver
operation.
H10
N/A
These two signals MUST be separated for
“Transceiverless” operation.
Transmitter inhibit inputs for Channel A of external
MIL-STD-1553 transmitters. To enable transmission on
Channel A, this input must be connected to logic “0”.
To force a shutdown of Channel A, a value of logic “1”
should be applied to the respective TX_INH input.
Digital transmit inhibit outputs. Connect to
TXINH_OUT_A inputs of an external MIL-STD-1553
transceiver. Asserted high to inhibit when not trans-
mitting on the respective bus.
TXINH_IN_A (I) H11
50k
Pulldown