Page #121 background imageLoading...
Page #121 background image
Flag
Number Flag Name
Hex
Code Description Action Required Event
25 Interface 19h Set when the tape drive detects a
problem with the SCSI, Fibre
Channel, or RS-422 interface.
Locate Error Code 8 or 9 in
“Drive Error Codes:
Single-character display (SCD)”
on page 100.
Warning
Event
26 Cooling Fan
Failure
1Ah A tape drive cooling fan failed. Fan failure inside tape drive
mechanism or tape drive
enclosure.
Warning
Event
27 Power Supply 1Bh A redundant power supply failed
inside the tape drive enclosure.
Check the enclosure users
manual for instructions on
replacing the failed power
supply.
A redundant power supply failed
inside the tape drive enclosure.
Check the enclosure users
manual for instructions on
replacing the failed power
supply.
Warning
Event
30 Hardware A 1Eh Set when a hardware failure
occurs that requires that you reset
the tape drive to recover.
A redundant power supply failed
inside the tape drive enclosure.
Check the enclosure users
manual for instructions on
replacing the failed power
supply.
Warning
Event
31 Hardware B 1Fh Set when the tape drive fails its
internal Power-On Self-Tests.
Note the error code on the
single-character display and see
in “Drive Error Codes:
Single-character display (SCD)”
on page 100 for the appropriate
instructions.
Warning
Event
32 Interface 20h Set when the tape drive detects a
problem with the SCSI, Fibre
Channel, or RS-422 interface.
Set when the tape drive detects a
problem with the SCSI, Fibre
Channel, or RS-422 interface.
Warning
Event
33 Eject media 21h Set when a failure occurs that
requires you to unload the
cartridge from the drive.
Unload the tape cartridge, then
reinsert it and restart the
operation.
Warning
Event
34 Download fail 22h Set when the tape drive detects a
problem with the SCSI, Fibre
Channel, or RS-422 interface.
Ensure that it is the correct FMR
image. Download the FMR image
again.
Warning
Event
36 Drive temperature 24h Set when the drive's temperature
sensor indicates that the drive's
temperature is exceeding the
recommended temperature of the
library.
See Error Code 1 in “Drive Error
Codes: Single-character display
(SCD)” on page 100.
Warning
Event
37 Drive voltage 25h Set when the drive detects that
the externally supplied voltages
are either approaching the
specified voltage limits or are
outside the voltage limits.
See Error Code 2 in “Drive Error
Codes: Single-character display
(SCD)” on page 100.
Warning
Event
38 Predictive failure 26h A hardware failure of the tape
drive is predicted. Call the tape
drive supplier helpline.
Predictive failure of drive
hardware
Warning
Event
Troubleshooting 99

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC ML3 and is the answer not in the manual?

Dell EMC ML3 Specifications

General IconGeneral
Number of Drives1
CategoryTape Library
Drive TechnologyLTO
Humidity20% to 80% (non-condensing)
Drive TypeLTO Ultrium
Maximum Capacity15 TB (compressed)
Interface6Gb/s SAS
Max Data Transfer Rateup to 750 MB/s (with compression)
Operating Temperature10°C to 35°C
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)