Chapter 5 Parameters|VFD-M-D Series
Revision Jan. 2007, MDE2, SW V1.05 5-87
8 - 05 Response Delay Time Unit: 0.5
Settings 00 ~ 200 msec Factory Setting: 00
This parameter is the response delay time after AC drive receives communication command
as shown in the following.
RS485 BUS
PC or PLC command
Handling time
of AC drive
Response Dela
y
Time
Response Message of AC Drive
Max.: 6msec
Pr.8-05
5.3 The Flow Chart for Parameter Settings
Multi-function
Input Terminal
setting
5-00~5-10
Door Width
Auto-tuning
2-22
2-23
2-24
2-25
Door Close/Open
Speeds setting
Open: 3-00~3-06
Close: 4-00~4-04
Door OpenAccel/Decel
Time Setting
3-07, 3-08
Door Close Accel/Decel
Time Setting
4-05, 4-06
Door Open Holding Torque
Door Close Holding Torque
3-12, 3-13
4-15, 4-16
B
Power on
Motor parameters
auto tuning
2-00
2-01
2-02
2-04
2-05
2-06
Door Control Mode
0-09
Distance
control
0-09=0, 1
PGsetting
2-11
2-12
2-13
2-14
Position Mode
0-15
0-17
A
Multi-step control
0-09=2,3,4
Multi-step speed
frequency setting
5-17~5-32
B
A
Re-open setting
4-10
4-12
4-17(In PG mode)
4-18(In PG mode)
Drive Control
Method
0-18
Source of the Operation
Command
0-12
Useing
FWD Close Door
REV Open Door
external switch to
control door open/close
Distance
control
0-09=0, 1
Multi-step control
0-09=2,3,4