Chapter 5 Parameters|VFD-M-D Series
5-26 Revision Jan. 2007, MDE2, SW V1.05
drive is stopped. The deceleration time has to be set accordingly.
(2) If the motor free running is allowed or the load inertia is large, it is
recommended to select “coast to stop”.
RUN
STOP
RUN
STOP
Frequency
Frequency
Time
Time
output
frequency
output
frequency
motor
speed
motor
speed
operation
command
operation
command
stops according to
decel eration time
free run to stop
ramp to stop and free run to stop
EF
Frequency
Frequency
frequency output
motor
speed
EF
operation
command
stops according to
decel eration time
When Pr.0-13 is set to 02 or 03
frequency
output
free run to stop
operation
command
When Pr.0-13 is set to00 or 01
motor
speed
0 - 14
Door Open/Close Control
Factory Setting: 00
Settings 00 Enable door open/close operation
01 Disable door open operation
02 Disable door close operation
0 - 15
Position Mode
Factory Setting: 00
Settings 00 No limit signal
01 Door open limit signal only
02 Door close limit signal only
03 Door open and close limit signal
04 Detect by PG number and also accept external door open
/
close limit
signal