EasyManuals Logo

Delta VFD-M-D series User Manual

Delta VFD-M-D series
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #132 background imageLoading...
Page #132 background image
Chapter 7 Troubleshooting |VFD-M-D Series
Revision Jan. 2007, MDE2, SW V1.05 7-7
7.10 Motor Speed cannot be Changed
Motor can run but
cannot change speed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
Check if the setting of the
max. frequency is too low
Check to see if frequency is
out of range (upper/lower)
boundaries
Modify the setting
Modify the setting
Yes
No
Yes
If the setting of
Pr.05-17toPr.05-31
is too high
Yes
If finished with
executing
Pr.05-15
If the setting of
Pr.05-00 to Pr.05-14
are the same
Is it in PLC mode
Press UP/DOWN key
to see if speed has
any change
If there is any change
of the signal that sets
frequency (0-10V and
4-20mA)
Check if the wiring between
M1~M6 to DCM is correct
Correct
wiring
Check if frequency for
each step is different
Check if the wiring of
external terminal is correct
Change frequencysetting
Check if accel./decel.
time is set correctly
Please set suitable
accel./decel. time by
load inertia
Maybe AC motor drive has malfunction or misoperation
due to noise. Please contact DELTA.
Change defective
potentiometer

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-M-D series and is the answer not in the manual?

Delta VFD-M-D series Specifications

General IconGeneral
BrandDelta
ModelVFD-M-D series
CategoryController
LanguageEnglish

Related product manuals