3. Periodical check Field Service Ver. 1.0 Apr. 2005
8
ineo 161
ineo 210
Maintenance
B. Option
*1: Actual durable cycle is the Life counter value.
*2: ineo 210 only
3.1.2 Cleaning parts
*1: Actual cleaning cycle is the Life counter value.
*2: ineo 210 only
No.
Classifi-
cation
Parts name
Qua
ntity
Actual
durable
cycle *1
Pats No. Descriptions
Ref.Page
in this
manual
1
DF-502
Pick-up Roller 1 120 K 4688-3032-XX
Replace those
three parts at the
same time.
See
each
Option
Service
Manual.
2 Paper Take-up Roller 1 120 K 4688-3033-XX
3 Separation Roller 1 120 K 4688-3034-XX
4
DF-605
*2
Pick-up Roller 2 200 K 4344-5003-XX
Replace those
three parts at the
same time.
5 Paper Take-up Roller 1 200 K 4582-3014-XX
6 Separation Roller 1 200 K 4582-3047-XX
7 PF-502 Feed Roller 2 150 K 4686-3371-XX
8
MB-501
Paper Take-up Roller 1 150 K 4687-3012-XX
9 Separation Roller Assy 1 150 K 4034-0151-XX
No.
Classifi-
cation
Parts name Actual cleaning cycle *1 Descriptions
Ref.Page
in this
manual
1 IR section Original Glass 80 K ☞ 19
2
DF-502
Pick-up Roller 30 K
See
each
Option
Service
Manual.
3 Paper Take-up Roller 30 K
4 Separation Roller 30 K
5 Registration Roller 30 K
6 Registration Roll 30 K
7 Exit Roller 30 K
8 Exit Roll 30 K
9 Transport Roll 30 K
10
Length Size Detection
Sensor (PC7/AF)
30 K
11
DF-605
*2
Pick-up Roller 50 K
12 Paper Take-up Roller 50 K
13 Separation Roller 50 K
14 Rollers and rolls 50 K
15 Scanning Guide 50 K
16
Reflective Sensor
Section
50 K