Field Service Ver. 1.0 Apr. 2005 10. Service Mode
105
ineo 161
ineo 210
Adjustment / Setting
10.3.6 ADMIN. REGISTRATION
• ADMINISTRATOR NUMBER REGISTRATION is used to register or change the adminis-
trator number required when entering the Admin. Management function of the Utility
mode.
<Step>
1. Using the 10-Key Pad, type the 6-digit administrator number (000000 to 999999) to be
registered or changed.
2. Press the [Yes] key to register the administrator number.
10.3.7 FIXED ZOOM CHANGE
• FIXED ZOOM CHANGE is used to change the fixed zoom ratios.
<Step>
1. Select the particular fixed zoom ratio to be changed.
2. Using the 10-Key Pad, enter the desired fixed zoom ratio.
Default Values and Setting Range of Fixed Zoom Ratios
A. Japan
B. Metric
C. Inch
D. China
Setting name Default fixed zoom ratio Setting range
REDUCTION2 70% 51% to 70%
REDUCTION1 81% 71% to 99%
EXPANSION1 122% 101% to 140%
EXPANSION2 141% 141% to 199%
Setting name Default fixed zoom ratio Setting range
REDUCTION2 70% 51% to 70%
REDUCTION1 81% 71% to 99%
EXPANSION1 115% 101% to 140%
EXPANSION2 141% 141% to 199%
Setting name Default fixed zoom ratio Setting range
REDUCTION2 64% 51% to 64%
REDUCTION1 78% 65% to 99%
EXPANSION1 121% 101% to 128%
EXPANSION2 129% 129% to 199%
Setting name Default fixed zoom ratio Setting range
REDUCTION2 70% 51% to 70%
REDUCTION1 81% 71% to 99%
EXPANSION1 115% 101% to 140%
EXPANSION2 141% 141% to 199%