10. Service Mode Field Service Ver. 1.0 Apr. 2005
104
ineo 161
ineo 210
Adjustment / Setting
G. CCD MOVE TO HOME
H. SCAN TEST
I. ADF WIDTH ADJ. (MAX)
J. ADF WIDTH ADJ. (MIN)
K. ADF SENSOR ADJUST
Purpose/Use To move the Scanner to its home position and fix it at the home position.
✽ When transporting the copier
Setting/
Procedure
• Pressing the Start key will move the Scanner toward the left from its standby position.
<Step>
1. Press the Start key to move the Scanner from the standby position to the home posi-
tion.
✽ Pressing the Stop key will bring the Scanner back to its original position.
Purpose/Use To check that the Exposure Lamp turns ON properly and the Scanner moves properly.
✽ When the scan motion is faulty
Setting/
Procedure
<Step>
1. Press the Start key to start the scan test.
✽ Pressing the Stop key will stop the scan test.
Purpose/Use To adjust the Original size detection VR.
✽ When PBA-VR board is replace
✽ When PBA-CONT board is replace
Setting/
Procedure
✽ Refer to the option service manual (DF-605) for details.
Purpose/Use To adjust the original size detection VR.
✽ When the scan motion is faulty
✽ When PBA-CONT board is replace
Setting/
Procedure
✽ Refer to the option service manual (DF-605) for details.
Purpose/Use To automatically adjust the detection level of original path sensor.
✽ When each sensor is replaced
✽ When original size detection error occurs
Setting/
Procedure