EasyManua.ls Logo

Develop ineo 161 - Page 95

Develop ineo 161
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Field Service Ver. 1.0 Apr. 2005 10. Service Mode
85
ineo 161
ineo 210
Adjustment / Setting
For ineo 210
G. FUSER TEMP. Ad (THICK)
<Temperature table for adjusting fusing temperature for special paper>
For ineo 161
For ineo 210
Setting value Paper width
Mode selected in Service’s Choice
Mode 1 Mode 3
Fusing Heater Lamp temperature (main/sub)
2
221 mm or more
200 °C
220 mm or less
1
221 mm or more
190 °C
220 mm or less
0 (default value)
221 mm or more
180 °C
220 mm or less
-1
221 mm or more
170 °C
220 mm or less
Purpose/Use To set the fusing temperature when thick paper is used.
When fusing failure occurs
Setting/
Procedure
The default setting is “0.
Setting range: -1 to +1
Setting value
Paper width
Mode selected in Service’s Choice
Mode 1 Mode 3
CD Fusing Heater Lamp temperature
1
251 mm or more 210 °C 200 °C
250 mm or less 210 °C 200 °C
0 (default value)
251 mm or more 210 °C 190 °C
250 mm or less 200 °C 190 °C
-1
251 mm or more 200 °C 180 °C
250 mm or less 190 °C 180 °C
Setting value
Mode selected in Service’s Choice
Mode 1 Mode 3
Fusing Heater Lamp temperature (main/sub)
1 210 °C
0 (default value) 200 °C
-1 190 °C

Table of Contents