OFFSET (Frequency)
The Offset determines the units of which the constant is converting the
frequency into.
ALARM MODE
NEVER - Alarms are turned off and will not trigger an alarm condition during
operation.
AUTO - Alarm occurs after the defined alarm delay only when the system is
active and controlling.
ALWAYS - Alarm occurs after the defined alarm delay during operate mode
and shutdown mode.
HIGH/LOW ALARM LIMIT (Frequency)
The High and Low Alarm limit values determine when an alarm is triggered
to warn when a certain condition is met that is set by user-defined
parameters.
ALARM DELAY
Amount of time delay in seconds that occurs before an alarm is triggered
based on user-defined sensor parameters.
HIGH/LOW SHUTDOWN (Frequency)
The system shutdowns automatically when High and Low Shutdown is
enabled and the alarm condition is met as defined in High and Low Alarm
Limits. Both High and Low Shutdown functionality is independent of each
other.
82 / SYSTEM PROGRAMMING