4.1.5 Weigh & Measurement Spec Setup Procedure
To Change the setting of the Weight & Measurement SPEC, if there is some SPEC need to alter.
KEY TO PRESS OPERATION
In the Weighing Mode, press
then turn On the Span Switch.
-- Go to Z mode
TO CLEAR DAILY TRANSACTION PRESS
KEY TO PRESS OPERATION
+ [1] [4] [2]
-- Go to Weight and Measure Specification Mode
-- To change the selection for the Spec, press the
Number of the selection.
-- Press ‘PRINT’ key to Save go to next Spec
-- Pres ‘-‘ key to go back to previous Spec
-- Press ‘PLU’ to save and exit
-- Press ‘Tare’ to exit without saving
KEY TO PRESS OPERATION
[0] To [1]
OR
&
Then
-- Select data. (Refer to Weight & Measurement
Spec setting)
-- To choose scale type
-- To set. (Save data and increase SPEC No)
Z
MODE
PRINT KEY
SP600: PRICE BASE FOR WEIGHED ITEMS
0: 100
g
BASE 1: 1k
g
BASE
SP601: AUTO-ZERO FUNCTION
0: NO AUTO-ZERO 1: AUTO-ZERO