DISPLAYMESSAGESANDFAULTFINDING
27080Issue1August98 4--11
PECchanged--newbuildinformation
Softwareupgradehasresultedinchangetobuilddatastoredin
printer.
Ifmessagedoesnotcorrespondtoasoftwarechange,call
DominoService.
PECchanged--newconfigurationdata
Configurationchangehasresultedinchangetobuilddatastored
inprinter.
Ifmessagedoesnotcorrespondtoaconfigurationchange,
callDominoService.
Pressuresensorinputerror
Failureatinputtosensor.
Checksensorconnections.Iffaultpersists,callDomino
Service.
Printdatageneratedtoolate
Printratetoofast.
Adjust print delay.
Printfailed--printdelaytooshort
Messagedatawasnotreceivedbeforethenextproductwas
detected.
Increaseprintdelayuntilanacceptablevaluecanbe
entered.Ifnecessary,adjustpositionofproductsensoror
printhead.Iffaultpersists,callDominoService.
PrintGooccurredwhileprinting
Nextproductwasdetectedbeforethecurrentmessagecompleted
printing.
Checksensorposition,messagelength.
Printlate--printdelaytooshort
Messagedatawasreceivedtoolateforthemessagetobe
generatedandprinted.
Iffaultpersists,callDominoService.