Programming
92 Service Instructions 1767 - 00.0 - 12/2016
The categories include the following enhanced machine functions:
• Production control (such as the stitch counter)
• Needle cooling
• Light barrier
Parameters are represented by a number from 00-99.
19.1.2 Buttons
The buttons of the control panel are divided into the following groups:
• Thread
• Programming
• Seam program
OP1000 buttons and functions
No. Button Function Reference
①
Thread button group
Start bartack • Sets the start bartack p. 96
Multiple start bartack • Sets the multiple start
bartack
p. 97
End bartack • Sets the end bartack p. 98
Multiple end bartack • Sets the multiple end
bartack
p. 99
Thread cutter • Activates or deactivates
the thread cutter
p. 99
Thread clamp • Activates or deactivates
the thread clamp
p. 99
Needle position after
sewing stop
• Sets the needle position
after sewing stop
p. 100
Sewing foot lift after
thread cutter
• Activates or deactivates
the sewing foot lift after
thread cutter
p. 100