Troubleshooting
114 Operating Instructions 513/533 - 01.0 - 09/2023
M-301 Memory
abnormal
Control panel memory data
abnormal.
Internal error: The user needs
to update the software of the
control panel.
M-302 Machine type
parameter error
The machine type data read by
the control panel is outside of
the set range.
Press the RESET button
to call up parameter 241
automatically and select and
save the corrected machine
type.
M-303 UK parameter
abnormal
Abnormal range of the
parameter that was read from
the EEPROM by the control
panel.
Press the RESET button to
call up the system menu and
restore the default setting.
M-304 Main PCB
parameter
abnormal
Abnormal range of parameters
received from the control by the
control panel.
Press the RESET button to
call up the system menu and
restore the default setting.
M-305 Normal seam
pattern
parameter
abnormal
During the use of seam pattern
parameters, the control panel
detects an abnormal parameter
range.
Press the RESET button to
call up the system menu and
restore the default setting.
M-306 Error
Seam pattern
number
The selected seam pattern is
not stored in ROM or has been
disabled. The seam pattern is
"0"
Press the RESET button to
confirm the seam pattern
number.
M-307 Seam pattern
data abnormal
While the sewing data of the
seam pattern is read by the
control panel, the system
detects an abnormal data
format.
Select different seam
patterns.
M-308 Sewing data too
great
The volume of the seam pattern
data is found to be too great
during the calculation.
Select different seam patterns
for sewing.
Error Description Possible cause Troubleshooting